Order for this Paper or Similar Assignment Writing Help

Fill a form in 3 easy steps - less than 5 mins.

Posted: February 26th, 2022

Medical Coding Reimbursement

Case 3

Procedure: Dual Chamber Implantable Cardioverter Defibrillator (ICD) Implantation Pre-Procedure Diagnosis: Hypertrophic Cardiomyopathy, NSVT, SSS, Near Syncope Procedure: The patient was brought to the Electrophysiology Lab in the fasting state and continuous electrocardiographic monitoring was instituted. Anesthesia was performed by Dr Kiss and will be dictated separately by him. The left subclavicular fossa was prepped and draped in the usual sterile fashion and 1% lidocaine was instilled for local anesthesia. The incision was made and the dissection was carried down to the level of the pectoralis major fascia where a subcutaneous pocket was formed using blunt dissection. The axillary vein was entered with a Micropuncture thin walled needle without difficulty at two separate locations, guided by ultrasound, and guide wires were advanced into the central venous circulation. Using the guide wires and two introducer sheaths, an ICD electrode was advanced to the right ventricular septum, and a pacing electrode was advanced to the right atrial appendage under fluoroscopic guidance. Each electrode was anchored to the underlying pectoralis major fascia with a single stitch of 2-0 non-absorbable suture. These leads were attached to a dual chamber ICD which was placed in the previously formed pocket with electrodes situated beneath it after the pocket had been flushed with saline solution. The ventricular electrode is a Medtronic Model # 6935M62 (Serial # TDL515430V). This is a bipolar, steroid-tipped, active fixation lead. The R wave was 10 mV, the pacing impedance was 600 Ohms, and the ventricular capture threshold was 0.75 V @ 0.5 ms. The HVB impedance was 76. There was no diaphragmatic pacing at 10 V. The atrial electrode is a Medtronic Model # 5076 (Serial # PJN8450680). This is a bipolar, steroid-tipped, active fixation lead. The P wave was 1.3 mV, the pacing impedance was 650 Ohms, and the atrial capture threshold was 1.3 V @ 0.5 ms. There was no diaphragmatic pacing at 10 V. The ICD pulse generator is a Medtronic Evera MRI DR. Model # DDMB1D4, Serial # PFZ622773S. This device is placed in the subcutaneous location. No defibrillation threshold testing was performed. The wound was closed with a running stitch of 3-O absorbable suture and the skin was closed with a running stitch of 4-O absorbable suture. Topical skin adhesive was placed over the incision. The patient tolerated the procedure well.

Tags: , , , , , , , , , , , , , , , , , , ,

Why choose us

You Want Quality and That’s What We Deliver

Top Skilled Writers

Our writing team is assembled through a rigorous selection process, where we handpick accomplished writers with specialized expertise in distinct subject areas and a proven track record in academic writing. Each writer brings a unique blend of knowledge and skills to the table, ensuring that our content is not only informative but also engaging and accessible to a general college student audience

Discounted Prices

Competitive pricing is a cornerstone of our service, where we balance affordability with exceptional quality. In offering the best writers at rates that rival other writing services, we ensure that students can access top-notch content without breaking the bank unnecessarily. Our fair and transparent pricing structure is designed to provide value for money, making us a go-to choice for students seeking high-quality writing services at an affordable price.

100% Plagiarism-Free

Academic integrity is paramount to our writing service, which is why we produce original research and writing content for every paper. Each piece of work is carefully written from scratch, ensuring that every sentence, paragraph, and page is authentic and free from plagiarism. Our rigorous quality control process involves thorough scanning of every final draft, guaranteeing that the content meets the highest standards of originality and academic integrity. With keen attention to citation and referencing, we ensure that every source is properly credited, giving you complete peace of mind. We also have the best plagiarism checkers like safeassign and turnitin thus providing similarity score for each paper.

How it works

When you decide to place an order with Dissertation Help, here is what happens:

Complete the Order Form

You will complete our order form, filling in all of the fields and giving us as much detail as possible.

Assignment of Writer

We analyze your order and match it with a writer who has the unique qualifications to complete it, and he begins from scratch.

Order in Production and Delivered

You and your writer communicate directly during the process, and, once you receive the final draft, you either approve it or ask for revisions.

Giving us Feedback (and other options)

We want to know how your experience went. You can read other clients’ testimonials too. And among many options, you can choose a favorite writer.